Air cooled chillers with Free Cooling technology and Turbocor compressors, TurboLine series.

 

Innovative chillers have been designed to comply with particularly high specification demands on air conditioning equipment and systems.

  • Turbocor compressors
  • 2-year warranty
  • Free Cooling technology
  • Environmentally friendly refrigerant R134A

 

Chilled water systems – Turbocor compressor – Refrigerant R134a

 

Wall mounted air conditioner FUJITSU R410 ECO
R134a refrigerant
R134a refrigerant
Turbocor compressors
Turbocor compressors
Free Cooling technology
Free Cooling technology
Axial fans
Axial fans
Cooling only version
Cooling only version
Flooded Shell & Tube exchanger
Flooded Shell & Tube exchanger
R513A refrigerant
R513A refrigerant
R134a refrigerant
R134a refrigerant
R134a refrigerant

Units with the refrigeration system containing R134a (GWP 1430) refrigerant.

Turbocor compressors
Turbocor compressors
Turbocor compressors

Semi-hermetic, two-stage, centrifugal Turbocor compressors, without lubrication system, with magnetically levitating rotor, thermal protection, discharge and suction check valves, stepless capacity control system provided by the built-in inverter, and automatic anti-cavitation system. The power supply system of the compressor is equipped with a set of electrolytic capacitors to maintain levitation in the event of a power failure, a power factor correction choke, and an EMI filter (electromagnetic compatibility).

Free Cooling technology
Free Cooling technology
Free Cooling technology

The device is equipped with an additional Free Cooling exchanger which uses low outdoor temperature for direct cooling.

Axial fans
Axial fans
Axial fans

Axial fans directly coupled to a three phase electric motor and external rotor, equipped with a grille protecting the fan located at the air outlet.

Cooling only version
Cooling only version
Cooling only version

The units in the cooling-only version provide the basic function of cooling water, chilled water or air, while other functions are optional.

Flooded Shell & Tube exchanger
Flooded Shell & Tube exchanger
Flooded Shell & Tube exchanger

High efficiency flooded shell and tube heat exchanger with one or two independent cooling circuits and one water circuit.

R513A refrigerant
R513A refrigerant
R513A refrigerant

Units with the refrigeration system containing R513A (GWP 631) refrigerant.

Technical specifications

Agregat

 

Wydajność

Pobór mocy

Temperatura Free Cooling*

Pobór mocy Free Cooling**

Zasilanie

Wymiary

Masa

Ładunek czynnika

 

kW

kW

°C

kW

V/pH/Hz

mm

kg

kg (CO2eq-T)

CHA/TTY/FC 1301-1

246

71

-2,5

10,8

400/3/50

2360/4000/2200

3040

108(154,440)

CHA/TTY/FC 1401-1

281

80

0,5

10,8

400/3/50

2360/4000/2200

3200

108(154,440)

CHA/TTY/FC 1701-1

333

94

-2,9

10,8

400/3/50

2360/5000/2200

3600

130(185,900)

CHA/TTY/FC 2201-1

400

116

0,0

14,4

400/3/50

2360/5000/2200

3700

142(203,060)

CHA/TTY/FC 2601-1

495

146

-2,8

18,0

400/3/50

2360/6200/2200

4500

178(254,540)

CHA/TTY/FC 2602-2

495

143

-2,8

18,0

400/3/50

2360/6200/2200

4700

178(254,540)

CHA/TTY/FC 3302-1

588

171

-2,3

18,0

400/3/50

2360/7200/2200

5150

198(283,140)

CHA/TTY/FC 3302-2

588

171

-2,3

21,6

400/3/50

2360/7200/2200

5400

198(283,140)

CHA/TTY/FC 4002-1

696

204

-0,5

21,6

400/3/50

2360/7200/2200

5500

230(328,900)

CHA/TTY/FC 4002-2

696

204

-0,5

21,6

400/3/50

2360/7200/2200

5700

230(328,900)

CHA/TTY/FC 4302-1

869

257

-0,2

25,2

400/3/50

2750/8400/2200

7700

285(407,550)

CHA/TTY/FC 4302-2

869

257

-0,2

25,2

400/3/50

2750/8400/2200

7800

285(407,550)

CHA/TTY/FC 4604-2

981

280

1,5

32,4

400/3/50

2750/10050/2200

9100

310(443,300)

CHA/TTY/FC 4603-1

1046

307

1,0

32,4

400/3/50

2750/10050/2200

8800

310(443,300)

CHA/TTY/FC 4804-1

1229

357

1,0

36,0

400/3/50

2750/11100/2200

10000

340(486,200)

CHA/TTY/FC 4804-2

1229

357

1,0

36,0

400/3/50

2750/11100/2200

10200

340(486,200)

CHA/TTY/FC 5004-1

1443

425

1,0

36,0

400/3/50

2750/11100/2200

10300

385(550,550)

CHA/TTY/FC 5004-2

1443

425

1,0

36,0

400/3/50

2750/11100/2200

10500

385(550,550)

 

Dane techniczne dotyczą wybranych modeli z oferty Klima-Therm. Producent stale udoskonala swoje wyroby – aby zweryfikować dane proszę skontaktować się z Autoryzowanym Dealerem. Nominalna wydajność chłodzenia wyznaczana jest dla następujących parametrów: tryb chłodzenia - temp. powietrza zewnętrznego +35°C, parametry wody chłodzącej (30% roztwór glikolu etylenowego) 15°C/10°C.

* Temperatura powietrza zewnętrznego przy której urządzenie osiąga wydajność podaną w tabeli w trybie FREE COOLING (bez pracy sprężarek)

** Pobór mocy w trybie FREE COOLING (bez pracy sprężarek)

Expand the entire table
Hide
Download

Do you need more documentation?

Check the Klima-Therm technical portal.
See the technical documentation portal

Explore projects

Find out where we installed chilled water systems
Browse references
Other products in this category