Condensing units with rotary compressors / Scroll, axial fans.
Condensing units are dedicated to heat exchangers of air handling units ? central air conditioning.
Condensing units are dedicated to heat exchangers of air handling units ? central air conditioning.
Units with the refrigeration system containing R410A (GWP 2088) refrigerant.
Single phase or three phase rotary compressor, equipped with an overload protective device (klixon), integrated into the motor and crankcase. If necessary, it can be fitted on rubber shock absorbers.
Scroll compressor with an oil sight glass. Installed with internal overheating protection and, if required, with a crankcase heater, fitted on rubber vibration dampers.
Axial fans directly coupled to a three phase electric motor and external rotor, equipped with a grille protecting the fan located at the air outlet.
Units in the cooling/heating version operate using the heat pump function. They can cool or heat water, chilled water or air.
The units in the cooling-only version provide the basic function of cooling water, chilled water or air, while other functions are optional.
Agregat
|
Wydajność C/G
|
Pobór mocy C/G |
Zasilanie |
Wymiary |
Masa |
|
kW |
kW |
V/pH/Hz |
mm |
kg |
MHA/K 15 |
4,5/ 4,8 |
1,3/ 1,4 |
230/1/50 |
1095/870/322 |
81 |
MHA/K 18 |
5,6/ 5,9 |
1,7/ 1,8 |
230/1/50 |
1095/870/322 |
83 |
MHA/K 21 |
6,8/ 7,3 |
2,0/ 2,2 |
230/1/50 |
1095/870/322 |
83 |
MHA/K 25 |
8,0/ 8,4 |
2,4/ 2,5 |
230/1/50 |
1095/870/322 |
87 |
MHA/K 31 |
9,2/ 9,7 |
2,8/ 2,9 |
230/1/50 |
1095/870/322 |
90 |
MHA/K 41 |
10,8/ 11,3 |
3,6/ 3,7 |
230/1/50 |
1095/870/322 |
92 |
MHA/K 51 |
13,2/ 13,7 |
3,8/ 3,9 |
400/3/50 |
1260/1164/500 |
109 |
MHA/K 61 |
15,8/ 16,8 |
4,8/ 5,0 |
400/3/50 |
1260/1164/500 |
111 |
MHA/K 71 |
19,1/ 19,9 |
5,9/ 6,1 |
400/3/50 |
1260/1164/500 |
113 |
MHA/K 81 |
21,2/ 22,0 |
6,8/ 7,0 |
400/3/50 |
1260/1164/500 |
115 |
MHA/K 91 |
26,4/ 27,4 |
8,1/ 8,3 |
400/3/50 |
1275/1850/1000 |
218 |
MHA/K 101 |
30,9/ 33,2 |
8,2/ 8,8 |
400/3/50 |
1275/1850/1000 |
232 |
MHA/K 131 |
36,6/ 40,9 |
10,5/ 10,9 |
400/3/50 |
1275/1850/1000 |
252 |
MHA/K 151 |
45,3/ 51,9 |
13,2/ 14,2 |
400/3/50 |
1275/1850/1000 |
266 |
Dane techniczne dotyczą wybranych modeli z oferty Klima-Therm. Producent stale udoskonala swoje wyroby – aby zweryfikować dane proszę skontaktować się z Autoryzowanym Dealerem. C - chłodzenie, G – grzanie. Nominalna wydajność chłodzenia i grzania wyznaczana jest dla następujących parametrów: tryb chłodzenia temperatura parowania 5°C, temperatura powietrza zewnętrznego 35°C; tryb grzania temperatura skraplania 40°C, temperatura powietrza zewnętrznego 7°C,