HomeProductsArrowArrowArrowCassette R410A - LRL - Standard
Back Back

Cassette R410A - LRL - Standard

Fujitsu
Find out more about the brand

Air conditioning configurator

close
Air conditioning configurator

Split air conditioner model intended for installation in suspended ceilings of rooms with a large surface area.

 

Thanks to the technologies used, in addition to its basic functions, which ensure comfort of use, the air conditioner has a series of other functions, such as exceptionally quiet operation or Wi-Fi communication.

  • 5-year warranty
  • Ventilation option
  • Wi-Fi communication
  • Additional air supply duct
  • Corrosion protection Blue Fin
  • Built-in condensate pump
Split type cassette air conditioner, AUYG - LRLE, 4-way airflow
See the most important functions
Automatic fan speed
Automatic fan speed
Auto-changeover
Auto-changeover
Up/down swing flaps
Up/down swing flaps
Auto restart
Auto restart
Blue Fin
Blue Fin
Fresh air supply
Fresh air supply
Filter sign
Filter sign
Connectable distributing duct
Connectable distributing duct
Drain pump as standard
Drain pump as standard
Weekly timer
Weekly timer
Economy operation
Economy operation
Automatic fan speed
Automatic fan speed
Automatic fan speed

The microprocessor automatically adjusts the air flow intensity to changes in the room temperature.

Auto-changeover
Auto-changeover
Auto-changeover

The unit automatically switches between cooling and heating modes depending on the temperature and room temperature settings.

Up/down swing flaps
Up/down swing flaps
Up/down swing flaps

They change the air supply direction vertically (auto swing).

Auto restart
Auto restart
Auto restart

In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.

Blue Fin
Blue Fin
Blue Fin

Additional corrosion protection of the exchanger of the outdoor unit.

Fresh air supply
Fresh air supply
Fresh air supply

The outside air can be brought into the room by equipping the indoor unit with ducts and an optional module.

Filter sign
Filter sign
Filter sign

LED signals the need for filter cleaning.

Connectable distributing duct
Connectable distributing duct
Connectable distributing duct

The systems enable connecting ducts distributing the air.

Drain pump as standard
Drain pump as standard
Drain pump as standard

The low casing (198 mm) can be fully utilised thanks to the built-in drain pump. This solution allows the ceiling to be installed directly under the unit without leaving space for the condensate drainage system.

Weekly timer
Weekly timer
Weekly timer

On/Off program available for each day of the week.

Economy operation
Economy operation
Economy operation

Restriction of the maximum current and power consumption.

Technical specifications

Indoor/outdoor unit model

EEC

C/H

SEER

SCOP

Capacity

C/H

Capacity

C/H

Power supply

Dimensions

Weight

Refrigerant charge

 

 

 

kW

kW

V/pH/Hz

mm

kg

kg (CO2eq-T)

AUXG30LRLE

AOYG30LETL

A++

A+

6,5

4,3

8,5

10,0

 

2,6

2,8

 

230/1/50

288x840x840

50x950x950

830x900x330

26

5,5

61

2,1 (4,4)

AUXG36LRLE

AOYG36LETL

A++

A+

6,3

4,2

10,0

11,2

 

3,1

3,0

 

230/1/50

288x840x840

50x950x950

830x900x330

26

5,5

61

2,1 (4,4)

AUXG45LRLE

AOYG45LBTC

--

--

EER 3,11

COP 3,51

12,1

13,5

 

3,9

3,8

 

230/1/50

288x840x840

50x950x950

914x970x370

26

5,5

75

2,9 (6,1)

AUXG45LRLE

AOYG45LETL

--

--

EER 3,22

COP 3,71

12,5

14,0

 

3,9

3,8

 

230/1/50

288x840x840

50x950x950

1290x900x330

26

5,5

86

3,35 (7,0)

AUXG54LRLE

AOYG54LETL

--

--

EER 3,01

COP 3,41

13,3

16,0

 

4,4

4,7

 

230/1/50

288x840x840

50x950x950

1290x900x330

26

5,5

86

3,35 (7,0)

AUXG36LRLA

AOYG36LATT

A++

A+

6,5

4,3

10,0

11,2

 

2,4

2,6

 

400/3/50

288x840x840

50x950x950

1290x900x330

26

5,5

104

3,45 (7,2)

AUXG45LRLA

AOYG45LATT

--

--

EER 3,35

COP 3,91

12,5

14,0

 

3,5

3,6

 

400/3/50

288x840x840

50x950x950

1290x900x330

26

5,5

104

3,45 (7,2)

AUXG54LRLA

AOYG54LATT

--

--

EER 3,21

COP 3,61

14,0

16,0

 

4,4

4,4

 

400/3/50

288x840x840

50x950x950

1290x900x330

26

5,5

104

3,45 (7,2)

Technical data regards selected models from Klima-Therm offer. The manufacturer still improves his products – in order to verify the data, please contact the Authorized Distributor. C - cooling, H - heating, air-flow rate parameters are given for the highest fan speed. Rated cooling and heating capacity is specified for the following parameters: cooling mode indoor temp.: 27 CDB / 19 CWB, outdoor temp.: 35 CDB / 24 CWB and heating mode indoor temp.: 20 CDB / 15 CWB, outdoor temp.: 7 CDB / 6 CWB.

Expand the entire table
Hide
Download

Do you need more documentation?

Check the Klima-Therm technical portal.
See the technical documentation portal

Are you an installer?

Join the "Meet the Climate" program and win unique prizes
Check the details