Air conditioning configurator

close
Air conditioning configurator

Split air conditioner model featuring an attractive design, high quality of the materials used and high energy efficiency parameters.

 

Thanks to the technologies used, in addition to its basic functions, which ensure comfort of use, the air conditioner has a series of other functions, such as exceptionally quiet operation or Wi-Fi communication.

  • 10-year warranty
  • Low GWP R32 refrigerant (675)
  • Wi-Fi communication
  • Large, quiet supply fan
  • Human sensor
  • Filter contamination sensor
Wall mounted split type air conditioner, ASYG - KGTB series, modern design
  • Rated cooling capacity: 2,0 / 4,2 kW
  • Rated heating capacity: 2,5 / 5,4 kW
  • DC Inverter technology
  • Maximum refrigerant piping length: 20 m
  • Maximum refrigerant piping height: 15 m
  • Refrigerant: R32
  • High EER / COP coefficients
  • Energy class A+++ (size 07,09,12)
  • Wide range of operating temperatures, cooling and heating capacity
  • Recommended operating temperature in cooling mode: - 10÷46°C
  • Recommended operating temperature in heating mode: - 15÷24°C
  • Special quiet operation mode of indoor and outdoor unit
  • Operation modes: auto, cooling, heating, fan, dry
  • Energy-saving functions: minimum temperature hold, quick heating, economy mode
  • Bidirectional air-flow
  • Human sensor
  • Connection with LAN network (Wi-Fi module as option)
  • High performance with an enlarged rotor diameter fan driven by DC engine
  • +10?C heat function
  • Innovative exchanger design
  • Simple control of the air-flow direction with use of the controller
  • Air-flow rate adjustment with use of the controller
  • Timer: weekly, daily, periodic
  • Options: UTY-RNRYZ3, UTY-RCRYZ1, UTY-RLRY, UTY-RSRY, UTY-RHRY, UTY-XCSXZ2, UTY-TWRXZ2, UTY-TFSXW1, UTY-XWZX, UTY-TERX, UTY-VTGX, UTY-VTGXV
  • Certifications: EUROVENT, PZH, GOOD DESIGN
See the most important functions
Automatic fan speed
Automatic fan speed
Auto-changeover
Auto-changeover
Up/down swing flaps
Up/down swing flaps
Auto restart
Auto restart
Human sensor
Human sensor
10°C HEAT operation
10°C HEAT operation
Sleep timer
Sleep timer
Weekly timer
Weekly timer
Weekly timer and ser
Weekly timer and ser
Wireless LAN control
Wireless LAN control
Low noise mode
Low noise mode
Economy operation
Economy operation
Powerful operation
Powerful operation
Automatic fan speed
Automatic fan speed
Automatic fan speed

The microprocessor automatically adjusts the air flow intensity to changes in the room temperature.

Auto-changeover
Auto-changeover
Auto-changeover

The unit automatically switches between cooling and heating modes depending on the temperature and room temperature settings.

Up/down swing flaps
Up/down swing flaps
Up/down swing flaps

They change the air supply direction vertically (auto swing).

Auto restart
Auto restart
Auto restart

In the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.

Human sensor
Human sensor
Human sensor

The human sensor detects the movement of people in the room, reducing the efficiency of the air conditioner when the room is empty. After their return, the device   automatically restores the previous operation mode.

10°C HEAT operation
10°C HEAT operation
10°C HEAT operation
Sleep timer
Sleep timer
Sleep timer

The microprocessor gradually changes room temperature to ensure comfortable sleep.

Weekly timer
Weekly timer
Weekly timer

On/Off program available for each day of the week.

Weekly timer and ser
Weekly timer and ser
Weekly timer and ser

This option allows the temperature for two time intervals for each day of the week to be set.

Wireless LAN control
Wireless LAN control
Wireless LAN control

The optional Wi-Fi adapter makes it possible to control the air conditioner using a factory app via a smartphone or tablet.

Low noise mode
Low noise mode
Low noise mode

The low noise mode of the outdoor unit: depending on installation conditions, the user may select the silent operation setting. The operating time can be set using the programmer.

Economy operation
Economy operation
Economy operation

Restriction of the maximum current and power consumption.

Powerful operation
Powerful operation
Powerful operation

Increased heating capacity at low temperatures means that the nominal heating capacity is maintained up to outdoor temperatures of -7°C. The new model can operate at outdoor temperatures as low as -20°C.

Technical specifications

Indoor/outdoor unit model

EEC

C/H

SEER

SCOP

Capacity

C/H

Input Power

C/H

Power Source

Dimensions

Weight

Refrigerant Charge

 

 

 

kW

kW

V/pH/Hz

mm

kg

kg (CO2eq-T)

ASYG07KGTB

AOYG07KGCA

A+++

A+++

8,52

5,12

2,0

2,5

 

0,4

0,5

 

230/1/50

270x834x215

524x799x290

10

30

0,75 (0,5)

ASYG09KGTB

AOYG09KGCA

A+++

A+++

8,52

5,11

2,5

2,8

 

0,55

0,56

 

230/1/50

270x834x215

524x799x290

10

30

0,75 (0,5)

ASYG12KGTB

AOYG12KGCA

A+++

A+++

8,51

5,10

3,4

4,0

 

0,8

0,9

 

230/1/50

270x834x215

524x799x290

10

31

0,85 (0,6)

ASYG14KGTB

AOYG14KGCA

A++

A+

7,11

4,31

4,2

5,4

 

1,2

1,3

 

230/1/50

270x834x215

524x799x290

10

32

0,85 (0,6)

 

Technical data regards selected models from Klima-Therm offer. The manufacturer still improves his products – in order to verify the data, please contact the Authorized Distributor. C - cooling, H - heating, air-flow rate parameters are given for the highest fan speed. Rated cooling and heating capacity is specified for the following parameters: cooling mode indoor temp.: 27 CDB / 19 CWB, outdoor temp.: 35 CDB / 24 CWB and heating mode indoor temp.: 20 CDB / 15 CWB, outdoor temp.: 7 CDB / 6 CWB.

ErP compliant documentation download here FUJITSU ErP

Expand the entire table
Hide
Download

Do you need more documentation?

Check the Klima-Therm technical portal.
See the technical documentation portal

Are you an installer?

Join the "Meet the Climate" program and win unique prizes
Check the details
Other products in this category